Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Forensic Sci Int Genet ; 69: 102999, 2024 03.
Article in English | MEDLINE | ID: mdl-38181588

ABSTRACT

The Spanish and Portuguese Speaking Working Group of the International Society for Forensic Genetics (GHEP-ISFG) organized a collaborative study on mutations of Y-chromosomal short tandem repeats (Y-STRs). New data from 2225 father-son duos and data from 44 previously published reports, corresponding to 25,729 duos, were collected and analyzed. Marker-specific mutation rates were estimated for 33 Y-STRs. Although highly dependent on the analyzed marker, mutations compatible with the gain or loss of a single repeat were 23.2 times more likely than those involving a greater number of repeats. Longer alleles (relatively to the modal one) showed to be nearly twice more mutable than the shorter ones. Within the subset of longer alleles, the loss of repeats showed to be nearly twice more likely than the gain. Conversely, shorter alleles showed a symmetrical trend, with repeat gains being twofold more frequent than reductions. A positive correlation between the paternal age and the mutation rate was observed, strengthening previous findings. The results of a machine learning approach, via logistic regression analyses, allowed the establishment of algebraic formulas for estimating the probability of mutation depending on paternal age and allele length for DYS389I, DYS393 and DYS627. Algebraic formulas could also be established considering only the allele length as predictor for DYS19, DYS389I, DYS389II-I, DYS390, DYS391, DYS393, DYS437, DYS439, DYS449, DYS456, DYS458, DYS460, DYS481, DYS518, DYS533, DYS576, DYS626 and DYS627 loci. For the remaining Y-STRs, a lack of statistical significance was observed, probably as a consequence of the small effective size of the subsets available, a common difficulty in the modeling of rare events as is the case of mutations. The amount of data used in the different analyses varied widely, depending on how the data were reported in the publications analyzed. This shows a regrettable waste of produced data, due to inadequate communication of the results, supporting an urgent need of publication guidelines for mutation studies.


Subject(s)
Chromosomes, Human, Y , DNA Fingerprinting , Humans , Microsatellite Repeats , Ethnicity/genetics , Mutation , Haplotypes , Genetics, Population
2.
J Infect Public Health ; 16(11): 1750-1760, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37738691

ABSTRACT

BACKGROUND: Mobile phones, used in billions throughout the world, are high-touch devices subject to a dynamic contamination of microorganisms and rarely considered as an important fomite to sanitise systematically. The emergence of SARS-CoV-2 resulted in the COVID-19 pandemic, arguably the most impactful pandemic of the 21st century with millions of deaths and disruption of all facets of modern life globally. AIM: To perform a systematic review of the literature exploring SARS-CoV-2 presence as a contaminant on mobile phones. METHODS: A systematic search (PubMed and Google Scholar) of literature was undertaken from December 2019 to March 2023 identifying English language studies. Studies included in this review specifically identified or tested for the contamination of the SARS-CoV-2 virus or genome on mobile phones while studies testing for SARS-COV-2 in environments and/or other fomites samples than but not mobile phones were excluded. RESULTS: A total of 15 studies with reports of SARS-CoV-2 contamination on mobile phones between 2020 and 2023 were included. Amongst all studies, which encompassed ten countries, 511 mobile phones were evaluated for the presence of SARS-CoV-2 contamination and 45% (231/511) were positive for SARS-CoV-2. All studies were conducted in the hospital setting and two studies performed additional testing in residential isolation rooms and a patient's house. Four studies (3 in 2020 and one in 2021) reported 0% contamination while two other studies (in 2020 and 2022) reported 100% of mobile phone contamination with SARS-COV-2. All other studies report mobile phones positive for the virus within a range of 4-77%. CONCLUSION: A total of 45% of mobile phones are contaminated with SARS-CoV-2 virus. These devices might be an important fomite vector for viral dissemination worldwide. Competent health authorities are advised/recommended to start a global implementation of mobile phone decontamination by introducing regulations and protocols in public health and health care settings such as the 6th moment of hand washing.

3.
Infect Dis Health ; 28(1): 19-26, 2023 02.
Article in English | MEDLINE | ID: mdl-35995707

ABSTRACT

BACKGROUNDS: In 2022, smartphone use continues to expand with the number of smartphone subscriptions surpassing 6 billion and forecasted to grow to 7.5 billion by 2026. The necessity of these 'high touch' devices as essential tools in professional healthcare settings carries great risks of cross-contamination between mobile phones and hands. Current research emphasises mobile phones as fomites enhancing the risk of nosocomial disease dissemination as phone sanitisation is often overlooked. To assess and report via a large-scale E-survey the handling practices and the use of phones by healthcare workers. METHODS: A total of 377 healthcare workers (HCWs) participated in this study to fill in an E-survey online consisting of 14 questions (including categorical, ordinal, and numerical data). Analysis of categorical data used non-parametric techniques such as Pearson's chi-squared test. RESULTS: During an 8-h shift, 92.8% (n/N = 350/377) use their phone at work with 84.6% (n/N = 319/377) considering mobile phones as an essential tool for their job. Almost all HCWs who participated in this survey believe their mobile phones could potentially harbour microorganisms (97.1%; n/N = 366/377). Fifty-seven respondents (15.1%) indicated that they use their phones while wearing gloves and 10.3% (n/N = 39/377) have never cleaned their phones. The majority of respondents (89.3%; n/N = 337/377) agreed that contaminated mobile phones could contribute to dissemination of SARS-CoV-2. CONCLUSION: Mobile phone use is now almost universal and indispensable in healthcare. Medical staff believe mobile phones can act as fomites with a potential risk for dissemination of microbes including SARS-COV-2. There is an urgent call for the incorporation of mobile phone sanitisation in infection prevention protocol. Studies on the use of ultraviolet-C based phone sanitation devices in health care settings are needed.


Subject(s)
COVID-19 , Cell Phone , Humans , Fomites , Cross-Sectional Studies , United Arab Emirates , SARS-CoV-2 , Health Personnel
4.
Genes (Basel) ; 13(8)2022 08 07.
Article in English | MEDLINE | ID: mdl-36011314

ABSTRACT

Y chromosome short tandem repeat polymorphisms (Y-STRs) are important in many areas of human genetics. Y chromosomal STRs, being normally utilized in the field of forensics, exhibit low haplotype diversity in consanguineous populations and fail to discriminate among male relatives from the same pedigree. Rapidly mutating Y-STRs (RM Y-STRs) have received much attention in the past decade. These 13 RM Y-STRs have high mutation rates (>10−2) and have considerably higher haplotype diversity and discrimination capacity than conventionally used Y-STRs, showing remarkable power when it comes to differentiation in paternal lineages in endogamous populations. Previously, we analyzed two to four generations of 99 pedigrees with 1568 pairs of men covering one to six meioses from all over Pakistan and 216 male relatives from 18 deep-rooted endogamous Sindhi pedigrees covering one to seven meioses. Here, we present 861 pairs of men from 62 endogamous pedigrees covering one to six meioses from the Punjabi population of Punjab, Pakistan. Mutations were frequently observed at DYF399 and DYF403, while no mutation was observed at DYS526a/b. The rate of differentiation ranged from 29.70% (first meiosis) to 80.95% (fifth meiosis), while overall (first to sixth meiosis) differentiation was 59.46%. Combining previously published data with newly generated data, the overall differentiation rate was 38.79% based on 5176 pairs of men related by 1−20 meioses, while Yfiler differentiation was 9.24% based on 3864 pairs. Using father−son pair data from the present and previous studies, we also provide updated RM Y-STR mutation rates.


Subject(s)
Chromosomes, Human, Y , Mutation Rate , Chromosomes, Human, Y/genetics , Humans , Male , Microsatellite Repeats/genetics , Pakistan , Pedigree
5.
Electrophoresis ; 43(18-19): 1911-1919, 2022 10.
Article in English | MEDLINE | ID: mdl-35899438

ABSTRACT

This article details the development of a single multiplex system amplifying 26 rapidly mutating Y-STR markers. A sequenced allelic ladder, constructed for calling alleles of all loci, is introduced. The multiplex system shows the ability to address the limitations of Y-STRs commercial kits in differentiating closely related males. The multiplex performed well in the prevalidation tests and showed great potential to be used in forensic casework.


Subject(s)
Chromosomes, Human, Y , Microsatellite Repeats , Alleles , Chromosomes, Human, Y/genetics , DNA Fingerprinting , Forensic Medicine , Haplotypes , Humans , Male , Microsatellite Repeats/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...